Specifying Thickness of Insulated Glass
The glass thickness and air space in the double glaze of units vary depending on the parameter of window and wind load. In order to choose the ideal glass thickness according to glass dimensions and their areas, the table prepared assuming an average 150kg/m2 wind load has been presented below.
Technical Details
Glass Thickness
|
Air Space
|
Max. area and dimension
|
Weight kg/m²
|
Production tolerance
|
|
|
|
|
|
Dimension mm
|
Area
m²
|
Thickness mm
|
Width height mm
|
|
|
|
3+3
|
6
|
1500
|
1.00
|
15.5
|
+0.4
|
0./+2
|
difference between corners
4 mm
|
|
9
|
1600
|
1.20
|
+1.4
|
|
12
|
1600
|
1.40
|
|
|
4+4
|
6
|
1600
|
1.50
|
20
|
+0.6
|
0./+2
|
|
9
|
1800
|
2.00
|
+1.6
|
|
12
|
2000
|
2.60
|
|
|
5+5
|
6
|
2100
|
3.00
|
25
|
+0.6
|
0./+3
|
|
9
|
2300
|
3.80
|
+1.6
|
|
12
|
2500
|
4.20
|
|
|
6+6
|
6
|
2500
|
5.00
|
29
|
+0.8
|
0,5/+2
|
|
9
|
2700
|
5.80
|
+1.8
|
|
12
|
3000
|
6.90
|
|
|